N3K-C3548P-XL
Specification |
|
|
Physical |
48 fixed SFP+
ports (1 or 10 Gbps) Dual
redundant hot-swappable power supplies Four
individual redundant hot-swappable fans One 1-PPS
timing port, with the RF1.0/2.3 QuickConnect connector type One
10/100/1000-Mbps management port One RS-232
serial console port Two USB ports Locator LED · Locator
LED button |
|
Performance |
960-Gbps
switching capacity Forwarding
rate of 720 mpps Line-rate
traffic throughput (both Layer 2 and 3) on all ports · Configurable
MTUs of up to 9216 bytes (jumbo frames) |
|
Typical
operating power |
· 112W |
|
Maximum power |
· 213W |
|
Typical heat
dissipation |
· 383
BTUs per hr |
|
Maximum heat
dissipation |
· 727
BTUs per hr |
|
Mode |
Normal
mode |
Warp mode |
Number of MAC
addresses |
64,000 |
8000 |
Number of
IPv4 unicast routes |
24,000 |
4000 |
Number of
IPv4 hosts |
64,000 |
8000 |
Number of
IPv4 multicast routes |
8000 |
8000 |
Number of
VLANS |
4096 |
|
Number of ACL
entries |
4096 |
|
Number of
spanning-tree instances |
Rapid
Spanning Tree Protocol (RSTP): 512 Multiple
Spanning Tree (MST) Protocol: 64 |
|
Number of
EtherChannels |
24 |
|
Number of
ports per EtherChannel |
24 |
|
Buffer size |
6 MB shared
among 16 ports; 18 MB total |
|
System memory |
16 GB |
|
Boot flash
memory |
16 GB |
|
Number of
power supplies |
2 (redundant) |
|
Power supply
types |
AC (forward
and reversed airflow) · DC
(forward and reversed airflow) |
|
Input voltage |
100 to 240
VAC |
|
Frequency |
50 to 60 Hz |
|
Power supply
efficiency |
89 to 91% at
220V |
|
Forward and
reversed airflow schemes Forward
airflow: Port-side exhaust (air enters through fan tray and power supplies
and exits through ports) Reversed
airflow: Port-side intake (air enters through ports and exits through fan
tray and power supplies) Four
individual, hot-swappable fans (3+1 redundant) |
|
|
Dimensions
(height x width x depth) |
1.72 x 17.3 x
18.38 in. (4.36 x 43.9 x 46.7 cm) |
|
Weight |
17.4 lb (7.9
kg) |
|
Operating
temperature |
32 to 104° F
(0 to 40°C) |
|
Storage
temperature |
-40 to 158° F
(-40 to 70°C) |
|
Relative
humidity (operating) |
10 to85%
noncondensing Up to 5 days
at maximum (85%) humidity · Recommend
ASHRAE data center environment |
|
Relative
humidity (nonoperating) |
5 to 95%
noncondensing |
|
Altitude |
0 to 10,000
ft (0 to 3000m) |
|